Bottle blowing air compressor is a specialized equipment widely used in the process of inflating plastic bottles in fields such as food, medicine, and chemical engineering. The use of a bottle blowing air compressor requires a series of operating steps, which will be explained in detail below.
Before using the bottle blowing air compressor, it is necessary to inspect and prepare the equipment. Firstly, the manufacturer of the medium pressure air compressor checks whether the equipment is in good working condition to ensure that all components are not damaged or loose. Then, check if the lubricating oil of the equipment is sufficient and make necessary additions. Clean the work area, ensure a clean working environment, and prepare the required plastic bottles and other related materials.
Start the device and insert the power plug into the power outlet to ensure that the device is powered on. Then, turn the operation switch of the device to the start position, and after the device starts and runs stably, proceed to the next step of operation.
Install the mold according to the required bottle diameter and shape, select the appropriate mold, and install it according to the requirements of the equipment manual. Usually, mold installation requires the use of specialized tools to ensure secure installation and good connection to the equipment's intake system.
Adjust the air pressure according to the different requirements of the plastic bottle, and adjust the appropriate air pressure. Usually, adjustments need to be made through the air pressure regulating valve on the device. During the adjustment process, it is necessary to pay attention to the stability and control range of the air pressure to ensure that it can meet the requirements of plastic bottle inflation.

The bottle blowing air compressor for starting the circulation system usually has a circulation system, which is used to recover and recycle the air. Before starting the circulating system, it is necessary to ensure that there is no accumulated water or debris inside the system to avoid damage to the equipment. After starting the circulation system, the device will automatically filter and heat the air, and send high-temperature and high-pressure air to the mold to inflate the plastic bottle.
Place the prepared plastic bottle in the mold and ensure that the bottle mouth aligns with the air inlet of the mold. Usually, in order to ensure the inflation effect, it is necessary to place the plastic bottle in a certain position in the mold and fix it with a fixing device to prevent the bottle from sliding or overturning.
After ensuring the correct position and fixation of the plastic bottle, start the inflation program according to the device's operating interface or button. The device will inflate the plastic bottle based on pre-set parameters. During the inflation process, it is necessary to carefully observe the changes in the bottle body and monitor the pressure and temperature changes during the inflation process through the pressure and temperature gauges on the equipment.
After the completion of exhaust and cooling inflation, the device will automatically stop inflation and begin to exhaust and cool. During the exhaust and cooling process, the equipment will cool the mold and plastic bottle through a cooling device and release excess gas. During this process, do not touch the mold and plastic bottle randomly to avoid burns.
After the equipment has completed exhaust and cooling, the plastic bottle can be removed. Before removing the plastic bottle, turn off the power switch of the device and be careful to prevent unnecessary accidents. Then, carefully remove the plastic bottle and conduct necessary inspections. If there are no issues with the bottle body, the next process or packaging can be carried out.
After completing the bottle blowing and inflation process, the equipment needs to be cleaned and maintained. Firstly, turn off the power supply of the device, and then clean the surface and interior of the device to remove any possible residual plastic debris or dirt. Next, maintain and add lubricating oil to the lubrication parts of the equipment. Regularly inspect and maintain equipment to ensure its normal operation and lifespan.
The above are the operating steps required to use a bottle blowing air compressor, hoping to be helpful to you. When using the equipment, please strictly follow the equipment manual and operating procedures, and pay attention to safety precautions to ensure the smooth progress of work and personal safety.